4.2 TERMINAL CONNECTION DRAWING
4.3 CAUTION FOR WIRING CONNECTION
Wiring material with resistance less than 5 per wire should be used to connect R.T.D. with this unit.・Ω
The Specified extension lead wire or the wire itself should be used to connect thermocouple with this unit as wiring material.・
In case this unit should be used close to the noise generators, please use shield-wires.・
Please do not wire the Input/Output lines inside of the same duct and the pipes of electric wires.
The signal wire of Input/Output should be away from power supply and loaded lines at least 50cm.・
For prevention of electric shock, ple ase do wiring connection only after turning off Power.
WARNING
・
This unit does not function f or approx. 4 seconds after turning on Power. (No function at Output side)
CAUTION
・
For prevention of , please make sure to confirm the name labels i.e. Input terminal・ mis wiring
Power source terminal beside the each wire.and etc.
OPERATE FLOW AND PARAMETER INFORMATION
5
55
5.
..
.
5.1 METHOD TO CHANGE EACH DISPLAY
Power ON Display type of Input/Output for confirmation
Press Mode Key more than 2 seconds
Mode Display Parameter Display
Press Mode Key more than 2 seconds
5.2 OPERATE FLOW
shows the existence of Option, or it may not be displayed by the other parameter.MODE DISPLAY
ABCDE
Return
!"##$!"##%#&#'())
Output to A.Process Variable Setting Value Alarm Alarm Output AT Start
Low Limit High Limit Setting DisplaySetting
PARAMETER DISPLAY
・For PID Control(10.Kind of Control”
!
”or”
"
”)
12347
*+#,#-#."#/##01
D Input/OutputProportional Band Integral Time erivative Time Proportional Cycle Kind of
・For ON/OFF Control(10.Kind of Control”
2
”or”
3
”)
56
4#5#
OFF Point PositionSensitivity
8 9 10 11 12
0#6!"##7"8#9:#
SV Limiter Low SV Limiter High Kind of Control PV Correction Value Manual Reset
13 14 15 16 17
;###<#=#>>4?())
℃ ゚ Kind of CommunicationAlarm Output Function Alarm Output Sensitivity Decimal Position Select / F
18 19 20 21 22
Return
@9A7"B3A##'!C#%())
Communication Communication Communication Response to 1 or 5.Lock Display
Parameter Speed Address Delay Time
12
1212
121
11
1
①②③④⑤⑥⑦⑧⑨⑩⑪⑫
−
−−
−−
−−
−
A
AA
AB
BB
Bb
bb
b
−
−−
−
POWER
POWERPOWER
POWER
SUPPLY
SUPPLYSUPPLY
SUPPLY
Alarm
AlarmAlarm
Alarm
Output
OutputOutput
Output
SSR
SSRSSR
SSR
Drive
DriveDrive
Drive
Output
OutputOutput
Output
Communication
CommunicationCommunication
Communication
Thermocouple
ThermocoupleThermocouple
Thermocouple
R.T.D.
R.T.D.R.T.D.
R.T.D.
Current
CurrentCurrent
Current
RS-485
RS-485RS-485
RS-485
RS-232C
RS-232CRS-232C
RS-232C
(A)
(A)(A)
(A) (B)
(B)(B)
(B)
S.G
S.GS.G
S.G (T)
(T)(T)
(T)(R)
(R)(R)
(R)
Relay
RelayRelay
Relay
Contact
ContactContact
Contact
Output
OutputOutput
Output
12VDC/
12VDC/12VDC/
12VDC/
24VDC
24VDC24VDC
24VDC
−
−−
−
Commenti su questo manuale